Electrical Power System


ℹ️ A conceptual overview of the Electrical Power System (EPS) can be found in our hardware repository, quetzal1-hardware. We recommend you read it first, if this is your first time here. Some terms mentioned throughout this document may be defined there.


Directory Description

This directory contains the flight software for the EPS. It was developed using Arduino and it contains the source files, as well as the necessary libraries.

The directory is organized as follows:

  1. src/EPS/: contains the firmware programmed into the EPS microcontroller.
  2. media/: contains miscellaneous images that may be of use and serve as reference to the user.

⚠️ Note that local library paths (e.g., src/TMP100/TMP100.h) are used for the libraries included in the main sketch, to avoid compiling libraries that may be named the same within your own system. This has been tested to compile correctly with the Arduino IDE 1.8.13 and 2.0.0.


Design of the EPS I2C sensor network

The EPS carried the following I2C sensors to monitor the power grid and the health of the on-board battery:

  1. 3X Texas Instruments, Cat. No. INA260 - Precision Digital Current and Power Monitors, each functioning as:
    • Solar Channel Monitor (SCM)
    • Main Bus Monitor (MBM)
    • Secondary Bus Monitor (SBM)
  2. 1X Texas Instruments, Cat. No. BQ27741-G1 - Single-Cell Li-Ion Battery Fuel Gauge
  3. 1X Texas Instruments, Cat. No. TMP100 - Temperature Sensor with I2C Interface

The following figure shows the layout of the internal EPS I2C network:

eps-network

The EPS μC itself was connected as a slave with the address 0x99 to the satellite´s main I2C bus, which had the On-Board Computer (OBC) as master. The EPS internal I2C bus (shown in the previous figure) was implemented using the SoftwareWire library from the Free Software Foundation, Inc. (available online at: SoftwareWire Library).

Design of the EPS Fault Protection Boards (FPB) network

The EPS incorporated four protection circuits denominated Fault Protection Boards (FPB). Each FPB was made up of two components connected in series: a power-distribution switch (Texas Instruments, Cat. No. TPS2551) and a high-side unipolar current shunt monitor (Texas Instruments, Cat. No. INA169). The FPBs were used to power up or down individual satellite systems (COMMS, ADCS, Payload, and battery heater) and monitor their power consumption [1].

The following figure shows the connections between the EPS μC and the FPBs:

fpb-diagram

The FPB switches had active-high enable pins that could be used to control the power supply of individual satellite systems. Thus, the enable pin of each FPB was connected to a digital output pin of the EPS μC. In this way, it could command the activation or deactivation of a system following the commands sent by the OBC via the main I2C bus.

The FPB monitors measured the current consumption of each system using a shunt resistor, and they translated these measured currents into analog output voltages. The monitors were adjusted via hardware so that sensed currents between 0 mA and 2 A would translate into analog voltages between 0 V and 2.5 V. The output pin of each monitor was connected to an analog input pin of the EPS μC, and the required conversion from analog voltages to currents was implemented in software.

The following picture shows the circuit schematic of the complete EPS μC pinout including the pins connected to the FPBs:

eps-pinout

Note that pin PD2 of the EPS μC was used as a digital output pin that was connected to the active-high enable pin of a 5V voltage regulator integrated on the EPS circuit board.


ℹ️ Further details regarding the electronic design of the Quetzal-1's EPS can be found in [1] and [2].


Software and sensor start-up

The EPS firmware was designed with the same structure of a typical Arduino script. The main script EPS.ino can be found here. The setup section of the code executed pin configuration of the microcontroller, activating the analog and digital pins connected to each of the EPS FPBs (ADCS, COMMS, Payload, Battery Heater). Subsequently, the μC initialized the internal EPS I2C bus and all the sensors connected to it. To implement fault tolerance during sensor start-up, the µC was programmed to attempt the initial configuration of each I2C sensor a maximum of three times, as shown in the following code snippet:

  // Initial configuration of the Solar Channel Monitor (INA260 No.1)
  int INA_TRY_COUNTER1 = 0;
  while (INA_TRY_COUNTER1 < 3){
    if (ina260_1.begin()){
        comm_flags[0] = 1;
        break;
    }
    INA_TRY_COUNTER1 += 1;
    if (INA_TRY_COUNTER1 == 3){
      comm_flags[0] = 0;
    }
  }

Any error during the start-up sequence of a sensor was recorded in a Communication Flags (CF) byte. The structure of the CF byte was the following:

Table 1: EPS Communication Flags (CF) byte (0 - Error; 1 - Success)

Bit 7 6 5 4 3 2 1 0
Description 0 0 0 Thermal Sensor Comm. Flag Battery Gauge Comm. Flag SBM Comm. Flag MBM Comm. Flag SCM Comm. Flag

If a sensor failed to communicate with the μC three times during start-up, then the μC would set that sensor’s CF flag to 0. Otherwise, it would set the sensor’s CF flag to 1. After finishing the configuration of all the sensors, the μC would evaluate the resulting CF byte. If the CF byte had a value different from 0x00, then the μC would set an eps_ready flag to a value of 1. This flag was retrieved by the OBC to determine if the EPS system had been initialized correctly. If the OBC received the eps_ready flag set to 0, it would command the EPS μC to execute a software reset and retry the configuration of all the sensors. After the setup, the μC would then start executing a loop every 10 ms without performing any specific action, unless the OBC commanded otherwise.

OBC-EPS Communication

Interruptions were enabled in the EPS μC so it could receive commands sent by the OBC via the satellite’s main I2C bus. A typical I2C transaction between EPS and OBC was executed in two steps:

  1. Write: a write action would be performed by the OBC to set the value of the WireCommand variable stored in the EPS μC.
  2. Read: the OBC would then perform a read action, triggering a switch-case portion of the EPS code. This switch-case would then execute a specific action depending on the value of the WireCommand variable previously set by the OBC.

Three different types of commands were implemented on the EPS software:

  1. Enable/disable commands: used to set or reset the enable pins connected to the FPBs; thus, activating or deactivating a specific system inside the satellite.
  2. Data retrieval commands: used to immediately send back the requested data to the OBC (e.g. temperature data, voltage data or all data the collected by EPS).
  3. Direct action commands used to activate (set to 1) one of the following internal EPS flags: collect_data, collect_SOC, collect_FPB, eps_reset. Subsequently, the microcontroller’s execution loop would perform the action corresponding to the activated flag, and it would deactivate (set to 0) the flag upon completion of the action.

The complete list of OBC-EPS commands can be found here.

Power grid monitoring

When the EPS μC was commanded by the OBC to collect data from all sensors, the collect_data flag would be activated, and the execution loop would then perform the collection of all EPS measurements. Firstly, the collect_ready flag would be deactivated to signal that the EPS μC was in process of monitoring the satellite’s power grid. Then, the μC would command each sensor to measure and return data for processing and storage. To implement fault tolerance during data collection, the μC was programmed to try to obtain data from each EPS sensor a maximum of three times and to record any error in a Transmission Flags (TF) byte. The structure of the TF byte was the following:

Table 2: EPS Transmission Flags (TF) byte (0 - Error; 1 - Success)

Bit 7 6 5 4 3 2 1 0
Description 0 0 0 Thermal Sensor Trans. Flag Battery Gauge Trans. Flag SBM Trans. Flag MBM Trans. Flag SCM Trans. Flag

If a sensor failed to transmit correct data back to the μC three times during collection, then the μC would set that sensor’s TF flag to 0. Otherwise, it would set the sensor’s TF flag to 1. Furthermore, error values were implemented to indicate the reason for a transmission failure. If a sensor failed to transmit data back to the μC due to I2C miscommunication, all variables used to store data from the specific sensor would be loaded with the 0xFD or 0x0FFD values (Transmission Error). If a sensor sent data back to the μC, but a measurement corresponding to a strictly positive quantity returned as a negative number, the incorrect variable would be reloaded with the 0xFE or 0x0FFE values (Negative Error). Lastly, if a sensor sent data back to the μC, but a measurement was out of a nominal operating range, the incorrect variable would be reloaded with the 0xFF or 0x0FFF values (Range Error).

It is important to mention that the Communication Flags (CF) byte also had an effect on the data collection process. If the CF flag of a specific sensor was set to 0, that meant that the sensor had failed its initial setup. Therefore, the EPS μC would bypass data collection for that faulty sensor to avoid I2C bus hang-up caused by attempting to retrieve data from it.

During data collection, the EPS μC also polled the analog voltages returned by each FPB current monitor. These analog voltages, mapped to the respective currents, were then compared to the overcurrent and short-circuit current limits hard-coded for each system. The ADCS and Payload systems were limited to 290 mA. The COMMS system was limited to 1 A. Lastly, the Battery Heater was limited to 450 mA. It is worth noting that these software limits added a layer of protection on top of the current limits that were set via hardware configuration of the FPB power switches.

A Fault Flags (FPBF) byte was used to record any overcurrent or short-circuit failure detected by the EPS μC when polling the FPBs. If the μC detected that a specific system was consuming a current above its overcurrent limit, the overcurrent flag for that system would be set to a value of 1 to indicate an error. Furthermore, a short-circuit could be automatically detected in hardware by the FPB power switches. In these instances, the switches would automatically stop current flow. Therefore, in the event that a switch was enabled by the EPS μC, but no current flow was detected, the short-circuit flag for that system would be set to a value of 1 (to indicate an error).

Additionally, the OBC was programmed to retrieve the FPBF byte from the EPS μC every time it commanded the EPS to activate a system. This was done to allow the OBC to issue a quick deactivation command to shut down a failing system. The FPBF byte structure is shown in the following table:

Table 3: EPS FPBF byte (SC - short-circuit; OC - overcurrent; 0 - All OK; 1 - Failure)

Bit 7 6 5 4 3 2 1 0
Description Heater SC Flag Payload SC Flag Comms SC Flag ADCS SC Flag Heater OC Flag Payload OC Flag COMMS OC Flag ADCS OC Flag

ℹ️ It is worth noting that the ADCS system was programmed in such a way that its sensors exited low power mode and executed their measurements after the EPS had finished its own measurements. For this reason, the EPS μC always detected that the ADCS was enabled but consuming almost 0 mA during ground tests (reduced quiescent current in low power mode). This caused the ADCS short-circuit flag to always be set to 1 even though there was no real short-circuit condition. Since the ADCS would always be in failure according to the FPBF byte, the OBC was programmed to ignore the ADCS short-circuit flag to avoid an accidental shutdown of the system when the satellite launched into space.


After the EPS μC finished collecting all the data, the collect_ready flag would be activated to indicate to the OBC that there was new data to be retrieved. The OBC would then command the EPS μC to send back all the collected data, and the EPS μC would subsequently deactivate the collect_ready flag again to indicate that there was no new data to be retrieved at the moment. The OBC could also command the EPS μC to directly measure the battery state of charge and the FPB currents without having to execute the complete set of measurements by activating the collect_SOC and collect_FPB flags, respectively. It could also command the EPS μC to execute a software reset by activating the eps_reset flag, which basically forced the program’s pointer to return to the zero position in the program memory. This allowed the EPS μC to execute the software setup again.