Notifications
You must be signed in to change notification settings - Fork 0
/
plugin.py
488 lines (421 loc) · 23.7 KB
/
plugin.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
# Domoticz Home Automation - homematicIP Radiator Thermostat eTRV
# For the homematicIP Radiator Thermostats HmIP-eTRV-B, HmIP-eTRV-2:
# * set the setpoint
# * get the actual temperature
# * get the low batery state
# * get the valve position
# * set the active profile
# Dependencies
# Library ElementTree (https://docs.python.org/3/library/xml.etree.elementtree.html#)
# NOTES:
# 1. After every change run: sudo service domoticz.sh restart
# 2. Change user message for battery state in constants LOWBATMSG...
# 3. Domoticz Python Plugin Development Documentation: https://www.domoticz.com/wiki/Developing_a_Python_plugin
#
# Author: Robert W.B. Linn
# Version: See plugin xml definition
"""
<plugin key="HMIP-eTRV" name="homematicIP Radiator Thermostat (HmIP-eTRV)" author="rwbL" version="1.3.0 (Build 20210118)">
<description>
<h2>homematicIP Radiator Thermostat (HMIP-eTRV) v1.3.0</h2>
<ul style="list-style-type:square">
<li>Set the setpoint (degrees C).</li>
<li>Get the actual temperature (degrees C).</li>
<li>Get the low battery state (true or false). Threshold is set in the HomeMatic WebUI.</li>
<li>Get the valve position (0 - 100%).</li>
<li>Set the active profile.</li>
<li>Supported are the devices HmIP-eTRV-B, HmIP-eTRV-2</li>
</ul>
<h2>Domoticz Devices (Type,SubType)</h2>
<ul style="list-style-type:square">
<li>Setpoint (Thermostat,Setpoint)</li>
<li>Temperature (Temp,LaCrosse TX3)</li>
<li>Battery (General,Alert)</li>
<li>Valve (General,Percentage)</li>
<li>Profile (Light/Switch,Switch,Selector)</li>
</ul>
<h2>Hardware Configuration</h2>
<ul style="list-style-type:square">
<li>Address (CCU IP address, default: 192.168.1.225)</li>
<li>IDs (obtained via XML-API script http://ccu-ip-address/addons/xmlapi/statelist.cgi):</li>
<ul style="list-style-type:square">
<li>Device ID HmIP-eTRV-B or HmIP-eTRV-2 (default: 1541)</li>
<li>Datapoint IDs(#5): SET_POINT_TEMPERATURE, ACTUAL_TEMPERATURE, LOW_BAT, LEVEL, ACTIVE_PROFILE as comma separated list in this order (defaults:1584,1567,1549,1576,1566)</li>
</ul>
<li>Note: After configuration update, the setpoint is 0. Click the setpoint to set the value.</li>
</ul>
</description>
<params>
<param field="Address" label="CCU IP" width="200px" required="true" default="192.168.1.225"/>
<param field="Mode1" label="Device ID" width="75px" required="true" default="1541"/>
<param field="Mode2" label="Datapoint IDs" width="200px" required="true" default="1584,1567,1549,1576,1566"/>
<param field="Mode5" label="Check Interval (sec)" width="75px" required="true" default="60"/>
<param field="Mode6" label="Debug" width="75px">
<options>
<option label="True" value="Debug" default="true"/>
<option label="False" value="Normal"/>
</options>
</param>
</params>
</plugin>
"""
# Set the plugin version
PLUGINVERSION = "v1.3.0"
PLUGINSHORTDESCRIPTON = "HmIP-eTRV"
## Imports
import Domoticz
import urllib
import urllib.request
from datetime import datetime
import json
import xml.etree.ElementTree as etree
## Domoticz device units used for creating & updating devices
UNITSETPOINTTEMPERATURE = 1 # TypeName: N/A; Type ID:242 (Name:Thermostat); Subtype ID:1 (Name:Setpoint); Create device use Type=242, Subtype=1
UNITACTUALTEMPERATURE = 2 # TypeName: Temperature
UNITLOWBAT = 3 # TypeName: Alert
UNITLEVEL = 4 # TypeName: Percentage
UNITACTIVEPROFILE = 5 # TypeName: Selector Switch
# Number of datapoints = must match number of index defined below
DATAPOINTS = 5
# Index of the datapoints from the datapoints list
# The datapoints are defined as a comma separated string in parameter Mode2
# Syntax:DATAPOINTINDEX<Type> - without blanks or underscores; start with 0!
DATAPOINTINDEXSETPOINTTEMPERATURE = 0
DATAPOINTINDEXACTUALTEMPERATURE = 1
DATAPOINTINDEXLOWBAT = 2
DATAPOINTINDEXLEVEL = 3
DATAPOINTINDEXACTIVEPROFILE = 4
# Tasks to perform
## Change the setpoint
TASKSETPOINTTEMPERATURE = 1
## Get values from the datapoints ACTUAL_TEMPERATURE, LOW_BAT, LEVEL
TASKGETDATAPOINTS = 2
## Set the active profile
TASKSETACTIVEPROFILE = 3
# User Messages - Change as required
LOWBATMSGOK = "OK"
LOWBATMSGNOK = "Niedrig"
class BasePlugin:
def __init__(self):
# HTTP Connection
self.httpConn = None
self.httpConnected = 0
# List of datapoints (#4) - SET_POINT_TEMPERATURE, ACTUAL_TEMPERATURE, LOW_BAT, ACTIVE_PROFILE
self.DatapointsList = []
# Task to complete - default is get the datapoints
self.Task = TASKGETDATAPOINTS
# Thermostat Datapoints, i.e. Setpoint, LowBat, Temperature
self.SetPoint = 0 # setpoint in C
self.Temperature = 0 # actual temperature
self.LowBat = "unknown" # low battery "true" or "false". init with unknown to get the initial value
self.Level = 0 # valve position 0 - 100%
self.Profile = 0 # active profile 1 - 3 - init with 0 to ensure getting the value ser first time
# The Domoticz heartbeat is set to every 60 seconds. Do not use a higher value as Domoticz message "Error: hardware (N) thread seems to have ended unexpectedly"
# The plugin heartbeat is set in Parameter.Mode5 (seconds). This is determined by using a hearbeatcounter which is triggered by:
# (self.HeartbeatCounter * self.HeartbeatInterval) % int(Parameter.Mode5) = 0
self.HeartbeatInterval = 60
self.HeartbeatCounter = 0
return
def onStart(self):
Domoticz.Debug(PLUGINSHORTDESCRIPTON + " " + PLUGINVERSION)
Domoticz.Debug("onStart called")
Domoticz.Debug("Debug Mode:" + Parameters["Mode6"])
if Parameters["Mode6"] == "Debug":
self.debug = True
Domoticz.Debugging(1)
DumpConfigToLog()
# if there no devices, create these
Domoticz.Debug("Devices:" + str(len(Devices)) )
if (len(Devices) == 0):
try:
Domoticz.Debug("Creating new devices ...")
## 1 - SET_POINT_TEMPERATURE - TypeName: Thermostat (Type=242, Subtype=1)
Domoticz.Device(Name="Setpoint", Unit=UNITSETPOINTTEMPERATURE, Type=242, Subtype=1, Used=1).Create()
Domoticz.Debug("Device created: "+Devices[UNITSETPOINTTEMPERATURE].Name)
## 2 - ACTUAL_TEMPERATURE - TypeName: Temperature (Type=80, Subtype=5)
Domoticz.Device(Name="Temperature", Unit=UNITACTUALTEMPERATURE, Type=80, Subtype=5, Used=1).Create()
Domoticz.Debug("Device created: "+Devices[UNITACTUALTEMPERATURE].Name)
## 3 - LOW_BAT - TypeName: Alert (Type=243, Subtype=22)
Domoticz.Device(Name="Battery", Unit=UNITLOWBAT, Type=243, Subtype=22, Used=1).Create()
Devices[UNITLOWBAT].Update( nValue=1, sValue=LOWBATMSGOK )
Domoticz.Debug("Device created: "+Devices[UNITLOWBAT].Name)
## 4 - LEVEL - TypeName: Percentage (Type=243, Subtype=6)
Domoticz.Device(Name="Valve", Unit=UNITLEVEL, Type=243, Subtype=6, Used=1).Create()
Domoticz.Debug("Device created: "+Devices[UNITLEVEL].Name)
## 5 - ACTIVE_PROFILE - TypeName: Selector Switch (Type=244, Subtype=62)
SelectorSwitchOptions = {"LevelActions": "|||",
"LevelNames": "Off|1|2|3",
"LevelOffHidden": "true",
"SelectorStyle": "0"}
Domoticz.Device(Name="Profile", Unit=UNITACTIVEPROFILE, Type=244, Subtype=62, Switchtype=18, Options=SelectorSwitchOptions, Used=1).Create()
Domoticz.Debug("Creating new devices: OK")
except:
Domoticz.Error("[ERROR] Creating new devices: Failed. Check settings if new hardware allowed")
else:
# NOT USED - if there are devices, go for sure and update options. Exampe selector switch
# Options = { "LevelActions": "", "LevelNames": Parameters["Mode3"], "LevelOffHidden": "false", "SelectorStyle": "0" }
Domoticz.Debug("Devices already created.")
# Heartbeat
Domoticz.Debug("Heartbeat set: "+Parameters["Mode5"])
Domoticz.Heartbeat(self.HeartbeatInterval)
# Create the datapoints list using the datapoints as defined in the parameter Mode2
## The string contains multiple datapoints separated by comma (,). This enables to define more devices.
DatapointsParam = Parameters["Mode2"]
Domoticz.Debug("Datapoints:" + DatapointsParam)
## Split the parameter string into a list of datapoints
self.DatapointsList = DatapointsParam.split(',')
# Check the list length against the constant DATAPOINTS
if len(self.DatapointsList) < DATAPOINTS:
Domoticz.Error("[ERROR] Datapoints parameter not correct! Number of datapoints should be " + DATAPOINTS + ".")
return
def onStop(self):
Domoticz.Debug("Plugin is stopping.")
# Send the url parameter (GET request)
# If task = actualtemperature then to obtain device state information in xml format
# If task = setpoint then set the setpoint usig switch using the self.switchstate
# The http response is parsed in onMessage()
def onConnect(self, Connection, Status, Description):
Domoticz.Debug("onConnect called")
if (Status == 0):
Domoticz.Debug("CCU connected successfully.")
self.httpConnected = 1
# request all datapoints for the device id to get the actual data for the defined datapoints
if self.Task == TASKGETDATAPOINTS:
## url example = 'http://192.168.1.225/addons/xmlapi/state.cgi?device_id=' .. ID_DEVICE;
url = '/addons/xmlapi/state.cgi?device_id=' + Parameters["Mode1"]
# set the new setpoint
if self.Task == TASKSETPOINTTEMPERATURE:
## url example = 'http://192.168.1.225/addons/xmlapi/statechange.cgi?ise_id=1584&new_value=
url = '/addons/xmlapi/statechange.cgi?ise_id=' + self.DatapointsList[DATAPOINTINDEXSETPOINTTEMPERATURE] + '&new_value=' + str(self.SetPoint)
# set the new profile
if self.Task == TASKSETACTIVEPROFILE:
## url example = 'http://192.168.1.225/addons/xmlapi/statechange.cgi?ise_id=1566&new_value=
url = '/addons/xmlapi/statechange.cgi?ise_id=' + self.DatapointsList[DATAPOINTINDEXACTIVEPROFILE] + '&new_value=' + str(self.Profile)
Domoticz.Debug(url)
# define the senddata parameters (JSON)
sendData = { 'Verb' : 'GET',
'URL' : url,
'Headers' : { 'Content-Type': 'text/xml; charset=utf-8', \
'Connection': 'keep-alive', \
'Accept': 'Content-Type: text/html; charset=UTF-8', \
'Host': Parameters["Address"], \
'User-Agent':'Domoticz/1.0' }
}
# Send the data and disconnect
self.httpConn.Send(sendData)
self.httpConn.Disconnect
return
else:
self.httpConnected = 0
Domoticz.Error("[ERROR] Failed to connect ("+str(Status)+") to: "+Parameters["Address"]+":"+Parameters["Port"]+" with error: "+Description)
return
def onMessage(self, Connection, Data):
Domoticz.Debug("onMessage called")
# If not conected, then leave
if self.httpConnected == 0:
return
# Parse the JSON Data Object with keys Status (Number) and Data (ByteArray)
## 200 is OK
responseStatus = int(Data["Status"])
Domoticz.Debug("STATUS=responseStatus:" + str(responseStatus) + " ;Data[Status]="+Data["Status"])
## decode the data using the encoding as given in the xml response string
responseData = Data["Data"].decode('ISO-8859-1')
## Domoticz.Debug("DATA=" + responseData)
if (responseStatus != 200):
Domoticz.Error("[ERROR] XML-API response: " + str(responseStatus) + ";" + resonseData)
return
# Parse the xml string
# Get the xml tree - requires several conversions
tree = etree.fromstring(bytes(responseData, encoding='utf-8'))
# Handle the respective task to update the domoticz devices
if self.Task == TASKGETDATAPOINTS:
Domoticz.Debug("TASKGETDATAPOINTS")
# init helper vars
atv = 0.0 #actualtemperaturevalue
lbv = "" #lowbatteryvalue
spvrm = 0.0 #setpointvalueraspberrymatic
spvdom = 0.0 #setpointvaluedomoticz
lvlv = 0 #levelvalue
pv = 0 #profilevalue
# Get the value for datapoint actual_temperature & update the device and log
## <datapoint name="HmIP-RF.000A18A9A64DAC:1.ACTUAL_TEMPERATURE" type="ACTUAL_TEMPERATURE" ise_id="1567" value="23.000000" valuetype="4" valueunit="" timestamp="1610965660"/>
actualtemperaturevalue = tree.find(".//datapoint[@ise_id='" + self.DatapointsList[DATAPOINTINDEXACTUALTEMPERATURE] + "']").attrib['value']
## convert the raspberrymatic value to float
atv = float(actualtemperaturevalue)
## update the device if raspmatic value not equal domoticz value
if atv != self.Temperature:
Devices[UNITACTUALTEMPERATURE].Update( nValue=0, sValue=str(round(atv,2)) )
Domoticz.Debug("T Update=" + Devices[UNITACTUALTEMPERATURE].sValue)
self.Temperature = atv
# Get the value for datapoint low_bat & update the device and log
lowbat = tree.find(".//datapoint[@ise_id='" + self.DatapointsList[DATAPOINTINDEXLOWBAT] + "']").attrib['value']
## Battery status: false=green (1), true=red (4); store the lowbat state
## update the device if raspmatic value not equal domoticz value
lbv = lowbat
if lbv != self.LowBat:
if lbv == "false":
Devices[UNITLOWBAT].Update( nValue=1, sValue=LOWBATMSGOK )
if lbv == "true":
Devices[UNITLOWBAT].Update( nValue=4, sValue=LOWBATMSGNOK )
Domoticz.Debug("B Update=" + Devices[UNITLOWBAT].sValue)
self.LowBat = lbv
# Get the value for datapoint set_point_temperature & update the device and log
setpointtemperaturevalue = tree.find(".//datapoint[@ise_id='" + self.DatapointsList[DATAPOINTINDEXSETPOINTTEMPERATURE] + "']").attrib['value']
## setpoint value raspberrymatic
spvrm = float(setpointtemperaturevalue)
## setpoint value domoticz
spvdomsvalue = Devices[UNITSETPOINTTEMPERATURE].sValue
Domoticz.Debug("SP DOMOTICZ sValue=" + spvdomsvalue)
try:
## check if the domoticz setpoint svalue is empty. if the case then set to raspberrymatic setpointvalue
if not spvdomsvalue:
spvdomsvalue = setpointtemperaturevalue
Devices[UNITSETPOINTTEMPERATURE].Update( nValue=1, sValue= str(spvrm) )
spvdom = float(spvdomsvalue)
## Devices[UNITSETPOINTTEMPERATURE].Update( nValue=1, sValue= str(setpointtemperaturevalue[0]) )
## Domoticz.Debug("SP RM=" + str(spvrm) + ", SP DOM=" + str(spvdom))
## Update the setpoint if changed by homematic or manual and not equal domoticz setpoint
if spvdom != spvrm:
Devices[UNITSETPOINTTEMPERATURE].Update( nValue=1, sValue= str(spvrm) )
Domoticz.Debug("SP Update=RM=" + str(spvrm) + ", DOM=" + str(spvdom))
except:
Domoticz.Error("[ERROR] Setpoint Update. Can not convert Domoticz sValue to float:" + str(spvdomsvalue))
# Get the value for datapoint level & update the device and log
levelvalue = tree.find(".//datapoint[@ise_id='" + self.DatapointsList[DATAPOINTINDEXLEVEL] + "']").attrib['value']
## convert the raspberrymatic value to an int times 100 to get the value between 0 - 100%
lvlv = float(levelvalue) * 100
## update the device if raspmatic value not equal domoticz value
if lvlv != self.Level:
Devices[UNITLEVEL].Update( nValue=0, sValue=str(round(lvlv,0)) )
Domoticz.Debug("L Update=" + Devices[UNITLEVEL].sValue)
self.Level = lvlv
# Get the value for datapoint active_profile & update the device and log
profile = tree.find(".//datapoint[@ise_id='" + self.DatapointsList[DATAPOINTINDEXACTIVEPROFILE] + "']").attrib['value']
## Active profile: 1-3; store the active profile
## update the device if raspmatic value not equal domoticz value
## the nvalue must be 2 to ensure the selector is on
## the svalue is the level between 10 - 30, means the profile 1 - 3 needs to be converted to 10 -30
pv = int(profile)
if pv != self.Profile:
Devices[UNITACTIVEPROFILE].Update( nValue=2, sValue=str(pv * 10) )
Domoticz.Debug("P Update=" + Devices[UNITACTIVEPROFILE].sValue)
self.Profile = pv
# Domoticz.Debug("TASKGETDATAPOINTS:" + Parameters["Key"] + ":T=" + str(atv) + ", SP=" + str(spvrm) + ", B=" + lbv + ", L=" + str(lvlv) + ", P=" + str(pv) )
# Domoticz.Log("TASKGETDATAPOINTS:" + Parameters["Key"] + ":T=" + str(atv) + ", SP=" + str(spvrm) + ", B=" + lbv + ", L=" + str(lvlv) + ", P=" + str(pv) )
if self.Task == TASKSETPOINTTEMPERATURE:
Domoticz.Debug("TASKSETPOINTTEMPERATURE")
# Update the thermostat
Devices[UNITSETPOINTTEMPERATURE].Update( nValue=1, sValue= str(self.SetPoint) )
# NOT REQUIRED = Devices[UNITSETPOINTTEMPERATURE].Refresh()
if self.Task == TASKSETACTIVEPROFILE:
Domoticz.Debug("TASKSETACTIVEPROFILE")
# Update the profile selector switch
Devices[UNITACTIVEPROFILE].Update( nValue=2, sValue= str(self.Profile * 10) )
# NOT REQUIRED = Devices[UNITACTIVEPROFILE].Refresh()
return
# Handle oncomand for:
# Set the setpoint - Create http connection, the setpoint is set in onConnect
# Set the active profile
def onCommand(self, Unit, Command, Level, Hue):
# onCommand called. Example:
# Unit 1 - UNITSETPOINTTEMPERATURE: Parameter: 'Set Level', Level: 18.5
# Unit 5 - UNITACTIVEPROFILE: Parameter: 'Set Level', Level: 20
Domoticz.Log("onCommand called for Unit " + str(Unit) + ": Parameter '" + str(Command) + "', Level: " + str(Level))
if (Unit == UNITSETPOINTTEMPERATURE):
## Set the new setpoint temperature
self.SetPoint = Level
Domoticz.Debug("T Setpoint=" + str(self.SetPoint))
# Create IP connection and connect - see further onConnect where the parameters are send
self.httpConn = Domoticz.Connection(Name="CCU-"+Parameters["Address"], Transport="TCP/IP", Protocol="HTTP", Address=Parameters["Address"], Port="80")
self.httpConn.Connect()
self.httpConnected = 0
self.Task = TASKSETPOINTTEMPERATURE
if (Unit == UNITACTIVEPROFILE):
## Set the new profile - the level is between 10 - 30, which must be converted to profile 1 - 3 (int therefor round)
if (Level > 0):
self.Profile = round(Level / 10)
Domoticz.Debug("P Profile=" + str(self.Profile))
# Create IP connection and connect - see further onConnect where the parameters are send
self.httpConn = Domoticz.Connection(Name="CCU-"+Parameters["Address"], Transport="TCP/IP", Protocol="HTTP", Address=Parameters["Address"], Port="80")
self.httpConn.Connect()
self.httpConnected = 0
self.Task = TASKSETACTIVEPROFILE
return
def onNotification(self, Name, Subject, Text, Status, Priority, Sound, ImageFile):
Domoticz.Debug("Notification: " + Name + "," + Subject + "," + Text + "," + Status + "," + str(Priority) + "," + Sound + "," + ImageFile)
def onDisconnect(self, Connection):
Domoticz.Debug("onDisconnect called")
def onHeartbeat(self):
self.HeartbeatCounter = self.HeartbeatCounter + 1
Domoticz.Debug("onHeartbeat called. Counter=" + str(self.HeartbeatCounter * self.HeartbeatInterval) + " (Heartbeat=" + Parameters["Mode5"] + ")")
# check the heartbeatcounter against the heartbeatinterval
if (self.HeartbeatCounter * self.HeartbeatInterval) % int(Parameters["Mode5"]) == 0:
try:
# Create IP connection
self.httpConn = Domoticz.Connection(Name="CCU-"+Parameters["Address"], Transport="TCP/IP", Protocol="HTTP", Address=Parameters["Address"], Port="80")
self.httpConn.Connect()
self.httpConnected = 0
self.Task = TASKGETDATAPOINTS
return
except:
Domoticz.Error("[ERROR] Check settings, correct and restart Domoticz.")
return
global _plugin
_plugin = BasePlugin()
def onStart():
global _plugin
_plugin.onStart()
def onStop():
global _plugin
_plugin.onStop()
def onConnect(Connection, Status, Description):
global _plugin
_plugin.onConnect(Connection, Status, Description)
def onMessage(Connection, Data):
global _plugin
_plugin.onMessage(Connection, Data)
def onCommand(Unit, Command, Level, Hue):
global _plugin
_plugin.onCommand(Unit, Command, Level, Hue)
def onNotification(Name, Subject, Text, Status, Priority, Sound, ImageFile):
global _plugin
_plugin.onNotification(Name, Subject, Text, Status, Priority, Sound, ImageFile)
def onDisconnect(Connection):
global _plugin
_plugin.onDisconnect(Connection)
def onHeartbeat():
global _plugin
_plugin.onHeartbeat()
#
## Generic helper functions
#
def DumpConfigToLog():
for x in Parameters:
if Parameters[x] != "":
Domoticz.Debug( "'" + x + "':'" + str(Parameters[x]) + "'")
Domoticz.Debug("Device count: " + str(len(Devices)))
for x in Devices:
Domoticz.Debug("Device: " + str(x) + " - " + str(Devices[x]))
Domoticz.Debug("Device ID: '" + str(Devices[x].ID) + "'")
Domoticz.Debug("Device Name: '" + Devices[x].Name + "'")
Domoticz.Debug("Device nValue: " + str(Devices[x].nValue))
Domoticz.Debug("Device sValue: '" + Devices[x].sValue + "'")
Domoticz.Debug("Device LastLevel: " + str(Devices[x].LastLevel))
return
"""
# <TODO>
## Sync the setpoint value in case the thermostat has been changed manual.
def syncSetpoint(self,setpoint):
Domoticz.Debug("syncSetpoint " + str(setpoint) )
## Set the new setpoint temperature based on the selector switch level
## Convert the level 0,10,20 ... to temperature 0,19,20,12 ...
self.SetPointLevel = Level
## Get the setpoint index 0,1,2 from the level to get the setpoint from the setpointlist
setpointIndex = Level
if setpointIndex > 0:
setpointIndex = int(round(Level/10))
## Get the setpoint temperature from the setpointlist
self.SetPoint = self.SetPointList[setpointIndex]
Domoticz.Debug("T Setpoint=" + self.SetPoint)
return
"""