Notifications
You must be signed in to change notification settings - Fork 61
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
err 100 #25
Comments
It means:
I should refine the error code, combining the t. |
Thank you having improve !
I am not a specialist and I still don't understand
I tried rev 1.0.11
the result is as follows :
=================================
Sample DHT11...
Read DHT11 failed, err=4112
=================================
Sample DHT11...
Read DHT11 failed, err=3088
=================================
Sample DHT11...
Read DHT11 failed, err=4112
=================================
Sample DHT11...
Read DHT11 failed, err=3088
=================================
it still doesn't work ....
can you help ?
Philippe
Le sam. 25 août 2018 à 04:09, winlin <notifications@github.com> a écrit :
… It means:
// Error to wait for start low signal.
#define SimpleDHTErrStartLow 100
I should refine the error code, combining the t.
—
You are receiving this because you authored the thread.
Reply to this email directly, view it on GitHub
<#25 (comment)>,
or mute the thread
<https://github.com/notifications/unsubscribe-auth/Aosoy68q53hYF-8OaB5km6ALZkw42dkNks5uULHjgaJpZM4WLld1>
.
--
Cordialement
Philippe Tiberghien
|
@Beguineur Please test 1.0.12 |
@winlinvip Could we open this one up again? I have the same issue and would like to know what err=4112 and err=3088 mean? |
I busted a DHT22 (no idea how ... but there you go) and I've seen both the 3088 and the 4112 errors. Reading the code, xx12 makes sense but xx88? I can't see any of your defines where that's set. I'm curious as although the sensors unquestionably misbehaving, it does give some sort of reading (it's just off by a few degrees). I use a switch... case ladder to help me with the issue (failing to pull start low) but I'll be darned if I get it to 3088 again - but even if I did, you don't define that! Any thoughts? I'm not really good enough to debug someone else's code. |
新增了宏定义获取错误时间和错误码: // Get the time duration from error.
#define SimpleDHTErrDuration(err) ((err&0xff00)>>8)
// Get the error code defined bellow.
#define SimpleDHTErrCode(err) (err&0x00ff) 使用参考Example: if ((err = dht11.read(&temperature, &humidity, NULL)) != SimpleDHTErrSuccess) {
Serial.print("Read DHT11 failed, err="); Serial.print(SimpleDHTErrCode(err));
Serial.print(","); Serial.println(SimpleDHTErrDuration(err)); delay(1000);
return;
} |
I tried with arduino DTH11
rev 1.0.10
and got the following error
Sample DHT11...
Read DHT11 failed, err=100
I don't know what err 100 means
The text was updated successfully, but these errors were encountered: