Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Updating dataset with Suzuki informer library (#8) #12

Merged
merged 2 commits into from
Sep 29, 2020
Merged

Updating dataset with Suzuki informer library (#8) #12

merged 2 commits into from
Sep 29, 2020

Conversation

skearnes
Copy link
Contributor

  • Updating dataset with Suzuki informer library

Kutchukian et al "Chemistry informer libraries: a chemoinformatics enabled approach to evaluate and advance synthetic methods"
Ref: Chem. Sci., 2016, 7, 2604
doi: 10.1039/c5sc04751j

  • Updating dataset with Pd CN informer library

Here uploaded is an enumerated pbtxt containing Pd catalyzed C-N coupling reactions informer library extracted from Figure_4D palladium catalyst/ligand section. A total of of 144 reactions covering the entries from 1 to 8 were constructed using the webtool from the reference: Kutchukian et al "Chemistry informer libraries: a chemoinformatics enabled approach to evaluate and advance synthetic methods" Chem. Sci., 2016, 7, 2604. (doi: 10.1039/c5sc04751j)

  • Add files via upload

This is a 1,152-rxn photoredox HTE screening study of a photodehalogenation reaction using various iridium(III) complex photocatalysts. Ref: Mdluli, V. et al ACS Catal. 2020, 10, 6977−6987. DOI: 10.1021/acscatal.0c02247. High-throughput Synthesis and Screening of Iridium(III)Photocatalysts for the Fast and Chemoselective Dehalogenation ofAryl Bromides. There are a few challenges observed during the reaction template preparation. 1) The combinatorial photocatalyst library prep contains multiple steps from [Ir(C^N)2Cl]2 dimers which is not documented, to formation of [Ir(C^N)2(N^N)]+. In order to show the combinatorial set for both CN and NN ligands, I did not use crude product function, this is similar to the dealing with previous precatalyst description. I only focus on the ligand SMILES and put detailed prep info under add preparation section. 2) This library is monitored using an unconventional colorimetric analysis with indicator dye to trap the dehalogened byproduct HBr. Also the targeted measurement is rate constant, not yield or selectivity. I used selectivity cell to add the rate constant result and use detail to clarify it. Since the indicator is the limiting reactant used to capture the 1st-order decay rate along with 8 different concentrations span from 0-1.4 mM across 8 rows per photocatalyst column on the 96-welll, based on the input requirement, I improvised by using the average mM with +/- range and detailed in the add prep section. The enumeration process looked pretty good. I noticed one error which I did not see in the previous Suzuki and CN cases. The volume unit shown in the input material as well as setup section does NOT match the generated template or graph, for example, the vial size in the web template was "mL", while the downloaded pbttext file showed "Liter" instead. I corrected manually to mL, when I enumerated, the web version showed Liter. The same happened in the input solvent volume section. I think overall this tool shows its flexibility to capture this very intricate HTE design and experiment setup. Please review and let me know what do you guys think.

  • Delete Photodehalogen_Merged_dataset_dataset.pbtxt

  • Delete enumerate_Pd_CN_dataset.pbtxt

  • Delete enumerate_Suzuki_dataset.pbtxt

  • Add files via upload

  • Add files via upload

  • Delete enumerate_CN_template_spreadsheet.zip

  • Delete enumerate_Suzuki_template_spreadsheet.zip

* Updating dataset with Suzuki informer library

Kutchukian et al "Chemistry informer libraries: a chemoinformatics enabled approach to evaluate and advance synthetic methods"
Ref: Chem. Sci., 2016, 7, 2604
doi: 10.1039/c5sc04751j

* Updating dataset with Pd CN informer library

Here uploaded is an enumerated pbtxt containing Pd catalyzed C-N coupling reactions informer library extracted from Figure_4D palladium catalyst/ligand section.  A total of of 144 reactions covering the entries from 1 to 8 were constructed using the webtool from the reference: Kutchukian et al "Chemistry informer libraries: a chemoinformatics enabled approach to evaluate and advance synthetic methods" Chem. Sci., 2016, 7, 2604. (doi: 10.1039/c5sc04751j)

* Add files via upload

This is a 1,152-rxn photoredox HTE screening study of a photodehalogenation reaction using various iridium(III) complex photocatalysts.  Ref: Mdluli, V. et al ACS Catal. 2020, 10, 6977−6987. DOI: 10.1021/acscatal.0c02247. High-throughput Synthesis and Screening of Iridium(III)Photocatalysts for the Fast and Chemoselective Dehalogenation ofAryl Bromides.  There are a few challenges observed during the reaction template preparation.  1) The combinatorial photocatalyst library prep contains multiple steps from [Ir(C^N)2Cl]2 dimers which is not documented, to formation of [Ir(C^N)2(N^N)]+.  In order to show the combinatorial set for both CN and NN ligands, I did not use crude product function, this is similar to the dealing with previous precatalyst description. I only focus on the ligand SMILES and put detailed prep info under add preparation section. 2) This library is monitored using an unconventional colorimetric analysis with indicator dye to trap the dehalogened byproduct HBr. Also the targeted measurement is rate constant, not yield or selectivity.  I used selectivity cell to add the rate constant result and use detail to clarify it.  Since the indicator is the limiting reactant used to capture the 1st-order decay rate along with 8 different concentrations span from 0-1.4 mM across 8 rows per photocatalyst column on the 96-welll, based on the input requirement, I improvised by using the average mM with +/- range and detailed in the add prep section.  The enumeration process looked pretty good.  I noticed one error which I did not see in the previous Suzuki and CN cases.  The volume unit shown in the input material as well as setup section does NOT match the generated template or graph, for example, the vial size in the web template was "mL", while the downloaded pbttext file showed "Liter" instead.  I corrected manually to mL, when I enumerated, the web version showed Liter.  The same happened in the input solvent volume section.  I think overall this tool shows its flexibility to capture this very intricate HTE design and experiment setup.  Please review and let me know what do you guys think.

* Delete Photodehalogen_Merged_dataset_dataset.pbtxt

* Delete enumerate_Pd_CN_dataset.pbtxt

* Delete enumerate_Suzuki_dataset.pbtxt

* Add files via upload

* Add files via upload

* Delete enumerate_CN_template_spreadsheet.zip

* Delete enumerate_Suzuki_template_spreadsheet.zip
@github-actions
Copy link

Summary: +0 -0 reaction IDs

@skearnes skearnes closed this Sep 29, 2020
@skearnes skearnes reopened this Sep 29, 2020
@github-actions
Copy link

Summary: +264 -0 reaction IDs

Copy link
Contributor

@connorcoley connorcoley left a comment

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Note for posterity: long description of additional photochemistry dataset in the PR description is not actually relevant to this PR

@skearnes skearnes merged commit 94c7277 into main Sep 29, 2020
@skearnes skearnes deleted the #8 branch September 29, 2020 18:52
skearnes added a commit to skearnes/ord-data that referenced this pull request Feb 8, 2021
…) (open-reaction-database#12)

* Updating dataset with Suzuki informer library (open-reaction-database#8)

* Updating dataset with Suzuki informer library

Kutchukian et al "Chemistry informer libraries: a chemoinformatics enabled approach to evaluate and advance synthetic methods"
Ref: Chem. Sci., 2016, 7, 2604
doi: 10.1039/c5sc04751j

* Updating dataset with Pd CN informer library

Here uploaded is an enumerated pbtxt containing Pd catalyzed C-N coupling reactions informer library extracted from Figure_4D palladium catalyst/ligand section.  A total of of 144 reactions covering the entries from 1 to 8 were constructed using the webtool from the reference: Kutchukian et al "Chemistry informer libraries: a chemoinformatics enabled approach to evaluate and advance synthetic methods" Chem. Sci., 2016, 7, 2604. (doi: 10.1039/c5sc04751j)

* Add files via upload

This is a 1,152-rxn photoredox HTE screening study of a photodehalogenation reaction using various iridium(III) complex photocatalysts.  Ref: Mdluli, V. et al ACS Catal. 2020, 10, 6977−6987. DOI: 10.1021/acscatal.0c02247. High-throughput Synthesis and Screening of Iridium(III)Photocatalysts for the Fast and Chemoselective Dehalogenation ofAryl Bromides.  There are a few challenges observed during the reaction template preparation.  1) The combinatorial photocatalyst library prep contains multiple steps from [Ir(C^N)2Cl]2 dimers which is not documented, to formation of [Ir(C^N)2(N^N)]+.  In order to show the combinatorial set for both CN and NN ligands, I did not use crude product function, this is similar to the dealing with previous precatalyst description. I only focus on the ligand SMILES and put detailed prep info under add preparation section. 2) This library is monitored using an unconventional colorimetric analysis with indicator dye to trap the dehalogened byproduct HBr. Also the targeted measurement is rate constant, not yield or selectivity.  I used selectivity cell to add the rate constant result and use detail to clarify it.  Since the indicator is the limiting reactant used to capture the 1st-order decay rate along with 8 different concentrations span from 0-1.4 mM across 8 rows per photocatalyst column on the 96-welll, based on the input requirement, I improvised by using the average mM with +/- range and detailed in the add prep section.  The enumeration process looked pretty good.  I noticed one error which I did not see in the previous Suzuki and CN cases.  The volume unit shown in the input material as well as setup section does NOT match the generated template or graph, for example, the vial size in the web template was "mL", while the downloaded pbttext file showed "Liter" instead.  I corrected manually to mL, when I enumerated, the web version showed Liter.  The same happened in the input solvent volume section.  I think overall this tool shows its flexibility to capture this very intricate HTE design and experiment setup.  Please review and let me know what do you guys think.

* Delete Photodehalogen_Merged_dataset_dataset.pbtxt

* Delete enumerate_Pd_CN_dataset.pbtxt

* Delete enumerate_Suzuki_dataset.pbtxt

* Add files via upload

* Add files via upload

* Delete enumerate_CN_template_spreadsheet.zip

* Delete enumerate_Suzuki_template_spreadsheet.zip

* Update submission

Co-authored-by: jun-li-2020 <71387083+jun-li-2020@users.noreply.github.com>
Co-authored-by: github-actions <github-actions@github.com>
This was referenced Jul 8, 2021
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
None yet
Projects
None yet
Development

Successfully merging this pull request may close these issues.

3 participants